Tap Tap to Zoom
FLIR Instruments DM64 TRMS Digital Multimeter with Temperature has been discontinued by FLIR Systems and is no longer available. Our product experts have helped us select these available replacements below.You can also explore other items in the Tools, Survival Gear, Hand Tools yourself to try and find the perfect replacement for you!
The FLIR DM64 is the right choice for professionals who install, inspect, and maintain HVAC systems. It includes microamp measurement to test flame sensors, LoZ mode to prevent ghost voltage, measures capacitance and frequency, and features a Type-K thermocouple input for temperature measurement. A flashing backlight and audible indication simplify the task of checking wiring connections and switch operation in noisy work environments; and probe-contact voltage detection helps you more precisely identify live wires.
Features/Specifications:
Drop test: 2 m IP Rating: IP40 Capacitance Range: Basic Accuracy 200.0 nF ±1.5% 200.0 µF ±1.5% 10 mF ±4.5% 10.00 mF ±5.0% Diode Test Range: 3.000 V Basic Accuracy: ±0.9% Frequency Range: 99.99 kHz Basic Accuracy: ±1.0% Resistance Range: Basic Accuracy 600.0 kΩ ±0.5% 6.00 MΩ ±0.3% 60.00 MΩ ±0.9% Thermocouple: -40 to 752.0°F DMM ± (1.0% + 3°F), -40 to 400°C DMM ± (1.0% + 1.5°C) VFD AC Voltage Range: 600.0 V RMS Basic Accuracy: ±1.0% Continuity check: Between 30 Ω and 480 Ω AC/DC LoZ V Range: 600.0 V Basic Accuracy: ±2.0% AC/DC mAmps Range: 600.0 mA Basic Accuracy: ±1.0% / ±0.7% AC/DC microAmps Range: 6000 µA Basic Accuracy: ±1.5% / ±1.0%